Our Products - Anesthesia Machine with Ventilator AJ-2105

Anesthesia Machine with Ventilator AJ-2105

Anesthesia Machine with Ventilator AJ-2105

(2 Vaporizers, 3 Gas)

Description

Features

  • The Ventilator adopts microcomputer control with high-definition 4” TFT color LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
  • The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose two kinds of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
  • High-definition five-tube flowmeter (oxygen, nitrous oxide, and air), designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
  • Reliable pneumatic transmission system.
  • Economic and proper configuration of technologies, optional as required by the Customer.
  • Modularized design and upgrading. Upgrading is available as required by the Customer.

 

TECHNICAL PARAMETERS

Part of Anesthesia Machine

  • Main body High-strength engineering plastic rack, light,
  • beautiful and corrosion resistant
  • Scope of application          adult, child
  • Gas source                 O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa
  • Flow meter                 O2 : 0.1~1.0L/min   1.1~10L/min
  • N2O: 0.1~1.0L/min   1.1~10L/min
  • Air : 0.1~10L/min
  • O2, N2O linkage and N2O Stopper
  •   When using nitrous oxide, oxygen concentration>25%;
  •   When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
  • Flow rate of rapid oxygen supply   25~75L/min
  • Low oxygen pressure alarm    There will be sound alarm when the oxygen pressure < 0.2MPa
  • Vaporizer                  It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%. Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
  • Respiratory circuit            working mode: all-close, semi-close, semi-open APL: 0.5~7 kPa
  • Respiratory Bellows          bellows for adults, tidal volume range:0~1500 ml bellows for children, tidal volume range:0~300 ml
  • anyone can be chosen for application as
  • required by the customer

Part of Ventilator

  • Display mode               High-definition 8.4” TFT color LCD screen display
  • Ventilation  mode           IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, IMV, VCV, PCV
  • Ventilation parameters        Tidal volume  20~1500 ml
  • Rate         1~99 bpm
  • SIMV rate     2~20 bpm
  • I:E           4:1~1:8
  • Inspiratory trigger pressure   -1.0~2.0 kPa
  • PEEP         0~2.0 kPa
  • Pressure range 1.0~6.0 kPa
  • SIGH        1.5 times the inspiratory time
  • (70-150 adjustable)
  • Inspiratory platform  0~50%
  • Parameters for ventilation monitoring   tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure – time waveform, flow rate – time waveform,PEEP,inspiratory trigger pressure, Inspiratory platform, autonomous inspiratory rate, lung compliance, airway resistance, flow-volume loop, pressure-volume loop
  • Monitoring of oxygen concentration     21%~100%
  • Security Alarm System
  • Oxygen Concentration alarm     upper limit setting range  21%~100%
  • low limit setting range    10%~80%
  • Airway pressure alarm   upper limit setting range  0.3~6.0 kPa
  • low limit setting range     0.2~5.0 kPa
  • Per-minute ventilation volume alarm   upper limit setting range   3.0~30L/min
  • low limit setting range   1.0~10L/min
  • Sustained high-pressure alarm    it will give alarm when stress have consistently
  • been higher than 2.5 kPa
  • Suffocation alarm              it will give sound and light alarm if there
  • is no tidal volume input for 15 seconds
  • Power alarm
  • Power                         AC 220V±10%     50Hz±1Hz

(UPS, Storage battery)

  • (Mechanical Arms)
  • (End-expiratory CO2 monitoring)
  • Items within brackets are optional.