High Frequency X-ray Radiograph System
200mA High Frequency X-ray Radiograph System AJ-X160 & AJ-X160A
- Description
Description
Feature
- It is installed with close-table graphical colorful LCD touch screen and wireless remote control exposure, which makes the operator easy to use.
- We incorporate the latest compact high-frequency and high-voltage X-ray generator, which ensure superior image quality, while the skin dose is low, to protect the patient better.
- Adopt the technology of kV and mAs numeral closed loop control, real-time control of the microprocessor, which ensures the accuracy and repeatability of the output dose.
- Be equipped with radiography parameter of multi-part, multi-posture, multi-body, adult -child physical characteristic, the operator can modify and save the parameter by himself, which makes the operation more conveniently.
- First high power combined high frequency high voltage X-ray source and high frequency inverter power supply, which can reduce energy loss from outside HV generator and cable. It makes good quality X-ray, beautiful appearance and convenience.
- Possess multiple automatic protection and fault clue function, which makes the operation safer and more reliable.
- The radiography table can float in any direction, electromagnetic braking, position the patient more convenience and accuracy.
- X-ray generator component can move round the axis of X-ray generator, cross arm and Pillar stand , be convenient with side and slanting direction projection and radiography of patient on the stretcher.
- Be equipped with the chest stand, which is used in the radiography of the head, chest, belly, pelvic cavity, backbone and periphery.
- Control console of graphic program controlled LCD touch screen is optional, which can set the radiography parameter and exposure in another room.
Specification
Item | AJ-X160 | AJ-X160A |
Output power | 15kW | 25kW |
Power supply | 220V 50Hz,
Capacity: ≥20kVA |
380V 50Hz,
Capacity: ≥40kVA |
Main inverter frequency | 40kHz | |
X-ray tube | Rotary anode, dual-focus,
Large focus: 0.6mm, Small focus: 0.3mm, Anode thermal capacity:212kJ (300kHu) Tube thermal capacity: 900kJ (1200kHu) |
Rotary anode, dual-focus,
Large focus: 1.3mm, Small focus: 0.6mm, Anode thermal capacity:212kJ (300kHu) Tube thermal capacity: 900kJ (1200kHu) |
Rotary anode speed | 3000rpm | |
Tube current | 200mA | |
Tube voltage | 40kV-125kV | |
mAs | 0.4-360mAs | |
Table radiography grids | Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:120cm;Stationary type:15″×18″ | |
Chest stand radiography grids | Grid density:103L/INCH;Grid ratio:10:1;Focusing distance:150cm;Stationary type:18″×18″ | |
Operation method | close-table graphic program controlled LCD touchable screen operation; wireless remote control exposure |
Table size | 2000×760mm |
Table height | ≤700mm |
Table transverse movement | ≥210mm |
Table longitudinal movement | ≥325mm |
Grids cassette holder movement | ≥560mm |
X-ray tube assembly center rotation | ≥±90° |
Rotation of the pillar | 4×90° |
Axial rotation | 0-35° |
SID | 450-1200mm |
Pillar movement along the table | ≥1370mm |
Limited time of analog light beam opening | About 30s |
Film size | 5″×7″-14″×17″(Table radiography) |
Film size | 5″×7″-17″×17″(Chest stand radiography) |
Chest stand up and down movement | 472~1470mm |
Standard Configurations
- New integral radiography table (with pillar) one unit
- Combined high-frequency high-voltage X-ray generator one set
- Colored LCD touch screen control box one unit
- Remote-control console (with software) one set
- Chest Stand (with imported filter grids) one unit